Please use this identifier to cite or link to this item:
http://cmuir.cmu.ac.th/jspui/handle/6653943832/71402
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Thatsanee Khongrangdee | en_US |
dc.contributor.author | Wasin Somboot | en_US |
dc.contributor.author | Jaroon Jakmunee | en_US |
dc.contributor.author | Tinakorn Kanyanee | en_US |
dc.date.accessioned | 2021-01-27T03:43:00Z | - |
dc.date.available | 2021-01-27T03:43:00Z | - |
dc.date.issued | 2020-11-10 | en_US |
dc.identifier.issn | 13482246 | en_US |
dc.identifier.other | 2-s2.0-85091771874 | en_US |
dc.identifier.other | 10.2116/analsci.20P158 | en_US |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85091771874&origin=inward | en_US |
dc.identifier.uri | http://cmuir.cmu.ac.th/jspui/handle/6653943832/71402 | - |
dc.description.abstract | A cost-effective flow-batch analysis approach with colorimetric measurement has been developed for sulfide ion determination in turbid water samples without using a conventional pump and valve. Under an acidic condition, sulfide ion was converted to hydrogen sulfide gas and liberated out from other complicated matrices. The porous membrane-based diffusion scrubber was utilized as a gas trapping unit for hydrogen sulfide gas separation/preconcentration. From the correlation of sulfide ion concentration and disappearance of sodium nitroprusside reagent detection by using a homemade LED-photodiode based colorimetry, a linear relationship of sulfide ion concentration and absorbance can be obtained with relative standard deviation (%RSD) less than 5%. The limit of detection was 5.6 μmol L-1. The proposed system was applied for sulfide ion determination in wastewater samples with the recoveries of 91.0 - 105.2%. The proposed system is a robust setup and able to handle turbid water samples without a sample filtering step. | en_US |
dc.subject | Chemistry | en_US |
dc.title | Colorimetric Determination of Sulfide in Turbid Water with a Cost-effective Flow-batch Porous Membrane-based Diffusion Scrubber System | en_US |
dc.type | Journal | en_US |
article.title.sourcetitle | Analytical sciences : the international journal of the Japan Society for Analytical Chemistry | en_US |
article.volume | 36 | en_US |
article.stream.affiliations | Chiang Mai University | en_US |
Appears in Collections: | CMUL: Journal Articles |
Files in This Item:
There are no files associated with this item.
Items in CMUIR are protected by copyright, with all rights reserved, unless otherwise indicated.